HP Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem User Manual
Page 125
Command line 125
Item
Description
LAGID (optional) The LAG ID on which to display statistics information. The LAG ID is in the format
lagNN, where NN is the LAG number.
PortID (optional) The ID of the port on which to display statistics information. The port ID is in the format
Examples
->show statistics enc0:3:X1
Displays statistics for uplink port X1 on interconnect module 3 of the primary enclosure
->show statistics enc0:1:Q1.1
Displays statistics for QSFP+ uplink port Q1.1 on interconnect module 1 of the primary
enclosure
->show statistics enc0:1:d3
Displays statistics for downlink port d3 on Ethernet interconnect module 1 of the
primary enclosure
->show statistics enc0:1:d1:v1
Displays statistics for subport v1 of downlink port d1 on Ethernet interconnect module
1 of the primary enclosure
->show statistics PortID=enc0:1:X1
Displays statistics for uplink port X1 on interconnect module 1 of the primary enclosure
->show statistics -summary LAGID=enc0:1:lag25
Displays aggregated statistics with selected counters for a given LAG ID on
interconnect module 1 of the primary enclosure
->show statistics LAGID=enc0:1:lag25
Displays aggregated statistics for a given LAG ID on interconnect module 1 of the
primary enclosure
In addition to the standard statistics, Virtual Connect also provides additional information on DCBX and QoS.
The QoS statistics are displayed for the specified physical port. The types of QoS statistics are in the format
of cosq
on the egress dot1p priority of the corresponding QoS traffic class. When QoS is not enabled, cosq3 is for
FCoE traffic and cosq0 is for regular Ethernet traffic.
The following table lists the types of QoS statistics displayed.
Item
Description
cosq
The accumulated transmitted byte count of unicast packets of the queue for
the specified port. For VC FlexFabric 10Gb/24-port module and VC
Flex-10 Enet module, the counter is not supported and the value is 0.
cosq
The accumulated transmitted packet count of unicast packets of the queue
for the specified port. For VC FlexFabric 10Gb/24-port module and VC
Flex-10 Enet module, the counter includes both unicast and multicast data.
cosq
The accumulated dropped packet count of unicast packet of the queue for
the specified port. For VC FlexFabric 10Gb/24-port module and VC
Flex-10 Enet module, the counter includes unicast and multicast data.
DCBX is the data center discovery and capability exchange protocol used by DCB devices to exchange
configuration information with directly-connected peers. The protocol can also be used for misconfiguration
detection and for configuration of the peer. In this release, the VC module adopts the DCBX specification to
implement the control state machine and three feature state machines:
•
Priority Group (PG)
- Virtual Connect 8Gb 20-port Fibre Channel Module for c-Class BladeSystem Virtual Connect FlexFabric-20.40 F8 Module for c-Class BladeSystem Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem Virtual Connect FlexFabric 10Gb24-port Module for c-Class BladeSystem