The ID for the poll port can be referenced from the output of the show

sflow-ports command.

PollingIntervals

(optional)

Specifies the polling interval which is the maximum number of seconds between

successive samples of the counters associated with these ports. Each value in the

list of polling interval has a corresponding port in the PollPorts list. The valid
polling interval range is from 1 to 65535 seconds. The default value is "10
seconds". Disable polling on a port using the remove sflow-ports

command.
Configure the module network using the set sflow-module command before

adding the module port for sampling or polling to a receiver.

Examples

->set sflow-ports Alpha SamplePorts=enc0:1:d1

Samplingrates=2048 Direction=Both PollPorts=enc0:1:d4

PollingIntervals=10

Modifies sample and polling ports

Item

Description

show sflow-ports

Display the port to be sampled or polled for a receiver.

Syntax

show sflow-ports []

Parameter

ReceiverName

(optional)

The name of an existing sflow receiver in the domain. A receiver name of "*"'

displays ports of all the receivers.

Examples

->show sflow-ports

Displays the sflow sample and polling ports

->show sflow-ports Alpha

Displays the Alpha sflow port

sflow-receiver

Configure the receivers.
Supported actions: add, help, remove, set, show

Item

Description

add sflow-receiver

Add a receiver.

Syntax

add sflow-receiver

IpAddress=[Port= <1-65535>]

[MaxHeaderSize=<128|256|512|1024>]

[MaxDatagramSize=<256-1500>]

Parameter

ReceiverName

(required)

Specifies the unique name of the receiver. A valid receiver name can have a
minimum of one character and maximum of 64 characters. Only alphanumeric

characters, -(hyphen), and _(underscore) are allowed. White spaces are not

allowed.

Properties

IpAddress (required)

Specifies the IP Address of the receiver where the sflow datagrams are sent

Port (optional)

Specifies the UDP port number of the receiver where the sflow datagrams are

sent. The valid range is from 1 to 65535. The default value is "6343".