INSTALLATION GUIDANCE

3.1 General Installation Information

The OPTIMASS mass flow meters provide high accuracy and excellent repeatability. Narrow
band pass digital filtering, and the mathematically modelled internal primary head design with
AST (Adaptive Sensor Technology) for the OPTIMASS sensor family provide exceptional immu-
nity to external disturbances caused by vibrations from nearby process equipment.

The accuracy of the flow meter is not affected by velocity profile.

The following installation guidelines are practical to implement, particularly if planned before
the OPTIMASS meter is first installed. For further dimensions or connections, please refer to
the relevant section.

For the OPTIMASS, in general, no special mounting requirements are necessary. However,
good general engineering practice for the installation of flow meters should still be observed.

The general guidelines described in this section are valid for the complete OPTIMASS family of
mass flow meters

The mass flow meters do not require any straight inlet or outlet runs.

Due to the weight of the meters we recommend the use of supports.

It is permissible to support the body of the meter.

The meter can be installed horizontally, in an upward sloping pipeline or vertically. For best
results, a vertical installation with flow in an upward direction is recommended.

This label on the meter shows the flow direction programmed into the converter in function
C.1.3.1

As default this is always in the direction of the ‘+’ arrow, i.e. left-to right as the label is viewed.

3.2 General Installation Principles