KROHNE OPTIMASS with MFC 300 EN User Manual
Page 112
112
Ref
Display
Description & Settings
C 3.x.13
Simulation
For sequence, see Test Level Menu, Fct. B 1
In the following descriptions of the outputs/inputs, "x“ denotes the terminals:
C 3.2 = A / C 3.3 = B / C 3.4 = C / C 3.5 = D (control input connected only to terminals A and B)
C 3.x
Status output X
C 3.x.1
Mode
•
error in device
•
application error
•
out of specification.
•
polarity, flow
•
overrange, flow
•
counter 1 preset
•
counter 2 preset
•
counter 3 preset
•
output W
•
output Y
•
output Z
•
off
C 3.x.2
"Output or input"
Dependent on selection
under Fct. 3.x.1, see
above
Appears only when "output W, Y or Z“ activated in Fct. C 2.x.1 Mode,
see above
•
same signal (only when
there are 2 status outputs)
Selection dependent on input or output
combination
•
polarity
•
over range
•
Range change (appears
only if set to current output
X in Fct. C 3.x.1, see status
output above)
•
off
C 3.x.3
Invert signal
Off
Active output generates high current at output, switch closed
On
Active output generates low current at output, switch open
C 3.x.4
Information
Displays: Serial No, Software No & calibration date of the circuit board
C 3.x.5
Simulation
For sequence, see Test Level Menu, Fct. B 1
C 3.x
Limit switch X
C 3.x.1
Measurement
•
Volume flow rate
•
Mass flow rate
•
Temperature
•
Density
•
Diagnosis1
•
Diagnosis 2
•
Flow Speed
•
Concentration 1
•
Concentration 2
•
Concentration Flow1
•
Concentration Flow 2
•
Diagnosis 3
C 3.x.2
Threshold
xxx.x ± x.xxx (set limit value, hysteresis) format, unit acc. to meas.
range selected and its upper range value. 2nd value (= hysteresis)
F
1st value
C 3.x.3
Polarity
• both polarities
Plus and minus values are used
• positive polarity
Negative values are set to 0%
• negative polarity
Positive values are set to 0%
• absolute
Absolute value is used
Choice of meas. value polarity, note flow direction, see C 1.5.1
C 3.x.4
Time constant
xx.x s
(setting range 000.0…100.0 s)
C 3.x.5
Invert signal
•
off
Active output generates high current at output, switch closed
•
on
Active output generates low current at output, switch open
C 3.x.6
Information
Displays: Serial No, Software No & calibration date of the circuit board
C 3.x.7
Simulation
For sequence, see Test Level Menu, Fct. B 1