KROHNE OPTIMASS with MFC 300 EN User Manual

Page 110

background image

110

Ref

Display

Description & Settings

C 3.x

Frequency output X

ctd...

C 3.x.4

Measurement

Volume flow rate

Mass flow rate

Temperature

Density

Diagnosis1

Diagnosis 2

Flow Speed

Concentration 1

Concentration 2

Concentration Flow1

Concentration Flow 2

Diagnosis 3

C 3.x.5

Range

0…100% (= unit dependent on measured variable selected)

C 3.x.6

Polarity

Both polarities

Plus and minus values are used

Positive polarity

Negative values are set to 0%

Negative polarity

Positive values are set to 0%

Absolute

Absolute value is used

Choice of meas. value polarity, note flow direction, see C 1.5.1

C 3.x.7

Limitation

-xxx…+xxx % (setting range -150%…+150%)

C 3.x.8

Low flow cutoff

xxxx.x…±xxxx.x unit dependent on measured variable selected

1st value

A

2nd value (hysteresis), values around “0“ are set to “0“

C 3.x.9

Time constant

xxx.x s (setting range 000.0…100.0 s)

C 3 x.10

Invert signal

Select:

Off

switch closes on every pulse, normally open

On

switch opens on every pulse, normally closed

C 3.x.11

Special function

This function is only at output B in devices with 2 frequency outputs
connected to terminals B + D or B + A See Fct. 3.x.11 below

Select:
Off

no special function

Phase shift to D

setting of all functions for output B via output D

Phase shift to A

setting of all functions for output B via output A

C 3.x.11

Phase shift in relation
to output B

This function is only available at output A or D, in devices with 2 fre-
quency outputs connected to terminals B + D or B + A See Fct. 3.3.11
above!

Select:

Off

no phase shift

0° shift

signal inversion possible

90° shift

signal inversion possible

180° shift

signal inversion possible

When Fct. C 3.5.6 Polarity is set to "both polarities“, the flow direction
is indicated (e.g. +90° or -90°)

C 3.x.12

Information

Displays the Serial No, Software No, and calibration date of the circuit
board

C 3.x.13

Simulation

For sequence, see Test Level Menu, Fct. B 1

In the following descriptions for the pulse output, "x“ denotes the
terminals:

C 3.2 = A

C 3.3 = B

C 3.5 = D

C 3.x

Pulse output X

C 3.x.1

Pulse shape

Automatic

approx. pulse width in [ms] =500 / (max. pulse rate in
[1/s])

Symmetrical: pulse duty factor approx. 1:1

Fixed

set in Fct. C 2.x.2