The above data are provided as a rough guide only.

Driver = Black and Grey.

Sensor A = White and Yellow. Sensor B = Green and Purple.

RTD = Red and Blue (530...550 ) at ambient temperature

Strain Gauge = 420...560

Resistance values outside these values could indicate a circuit failure. Meter may be in
start-up or have measuring errors.

All circuit should be isolated from ground (meter case) and each other: >20M . If circuits
are shorting to ground, meter may be in start-up.

Caution:

If the measuring tube/s fail, process fluid can leak into the outer casing. If this happens,
depressurise the meter and remove it from the process line as soon as it safe to do so.

OPTIMASS 2000

Resistance (Ohm)

Driver

Sensor A/B

Size 100

240

78

Size 150

240

64

Size 250

168

78