INSTRUMENT DESCRIPTION
2.1 Scope of Delivery
When unpacking your meter, please ensure that no visible damage has occurred during trans-
portation. If damage has occurred, please contact the carrier for claims.
Your high quality instrument has been fully tested and checked before shipping. The following
items should be included with your instrument unless otherwise requested:
1.
OPTIMASS Mass Flow Meter
2.
Separate Converter with remote converter wall mount (not for compact version)
3.
CD-ROM & Quick Start Guides
4.
Screw driver for terminal connections
5.
Calibration certificate
6.
Factory and Material certification, if ordered.
If any of these items are missing, please contact your nearest KROHNE Office or representative
(see back page).
2.1.1 Flange Versions
If your meter has been ordered with a flange connection, this will be supplied as per your order
and the flange specification is stamped on the outer edge of the flange.
Please check this specification against your original order and refer to the appropriate section
in this handbook.
2.1.2 Hygienic Versions
If your meter was ordered with a hygienic connector, it should be noted that the ‘O’ ring seals
between the meter and process pipework are NOT normally supplied.
If the hygienic connection is via an adaptor, then ‘O’ rings (material EPDM) are supplied in
order to make the connection between the meter and the adaptor. Please note that other
materials are available on request.
‘O’ rings are not normally supplied for the seal between the adaptor connection and process
pipework.
Adaptor connections may also be supplied loose, dependng upon type supplied.
For DIN11864-2 connections, ‘O’ rings and counter flanges are not supplied as standard but
are available on request.
2.1.3 Remote Field/Wall/Rack Conveter
The OPTIMASS range of massflow meters are normally supplied with the converter integrally
fitted. If you have specified a remote converter, the meter will be supplied with the converter
as a separate unit, together with a wall/pipe mounting bracket and a connection box mounted
to the meter.
In order to comply with 3A approval, all unused holes MUST be plugged and unused threads
MUST be covered or removed!
If ordered with the meter, cabling is supplied loose and IS NOT pre-prepared!
Wall Converter
If specified at the time of ordering, the meter will be supplied with a plastic wall mounted con-
verter that can be mounted on a wall or a pipe The housing material is Polyamide - polycar-
bonate.
Please note that the wall converter has not been 3A approved for hygienic applications.
19” Rack Mount Converter
If specified at the time of ordering, the meter will be supplied with a 19” rack mounted convert-
er