beautypg.com

KROHNE OPTIMASS with MFC 300 EN User Manual

Page 76

background image

76

Power Connection (Compact & Field versions)

Power Connection (Wall Version)

Power Connection (19” Rack Version)

N

L

D-

D

C-

C

B-

B

A+

A-

A

1

1

2

1

2

4

3

1

Earth Terminal (PE)

2

Neutral Connection

3

Live Connection

4

Cover in closed position after electrical connections have been made.

1

N (L-)

2

L (L+)

Earth connection MUST be parked on the earth tab inside the power compartment.

1

Connection via standard IEC socket