KROHNE OPTIMASS with MFC 300 EN User Manual
Page 113
113
Ref
Display
Description & Settings
C 3.x
Control input X
C 3.x.1
Mode
•
off
•
zero output + stop cnt.
(not display)
•
stop all counters
•
stop counter 1, 2 or 3
•
reset all counters
•
reset counter 1, 2 or 3
•
error reset
•
hold all outputs
(not display, not counters)
•
hold output W, Y or Z
•
all outputs zero
(not display, not counters)
•
output W, Y or Z zero
•
range change W, Y or Z
•
zero calibration
Note! If two control inputs are provided, they should not be set to the
same operating mode; if they are, only the control input connected to
Term. A is in function!
C 3.x.2
Invert signal
•
off
High current at input, switch closed activates function
•
on
Low current at output, switch open activates function
C 3.x.3
Information
Displays the Serial No, Software No, and calibration date of the circuit
board
C 3.x.4
Simulation
For sequence, see Test Level Menu, Fct. B 1
C4 I/O Totaliser
C 4.y
Totaliser 1, 2 or 3
All functions and settings for both counters are the same! In the fol-
lowing descriptions the “y“ indicates the counter:
Totaliser 1 = C 3.1
Totaliser 2 = C 3.2
Totaliser 3 = C 3.3
C 4.y.1
Function of Totaliser
Incremental Total
counts only positive values
Decremental Total
counts only negative values
Absolute Total
counts positive and negative values
off
counter is disabled
C 4.y.2
Measurement
•
volume flow
•
mass flow
•
concentration total1
•
concentration total2
C 4.y.3
Low flow cutoff
xxxx.x … ±xxxx.x unit dependent on measured variable selected
1st value A 2nd value (hysteresis), values around “0“ are set to “0“
C 4.y.4
Time constant
xx.x s
(setting range 000.0…100.0 s)
C 4.y.5
Preset value
x.xxxxx in the unit selected, max. 8 places (see Fct. C 4.7.10 or 13),
Status output X becomes active when value is reached. Status output
X mode (see Fct. C 3.x.1) must be set to Counter 1/2/3 Preset
C 4.y.6
Reset Total
•
yes
•
no
C 4.y.7
Set Total
Set initial counter value (overwrites current reading)
Cancel
g
>
return without simulation
Set Value
g
>
set value
g
>
query “set counter?“ No - Yes
>
execute with
g
C 4.y.8
Stop Totaliser
Select:
•
yes
•
no
C 4.y.9
Start Totaliser
Select:
•
yes
•
no
C 4.y.10
Information
Displays the Serial No, Software Number and calibration date of the
circuit board.