PASS-FAIL MODE

65

65

65

65

Frequency (except
Rdc)

Press the Left/Right key repeatedly to
move the cursor to Frequency, and use
the numerical and unit keys to enter the
value.

2.00

195.00 kHz

Vac

Frequency step
resolution

For frequency increase/decrease using Up/Down
keys, fine and coarse step settings are available.

Press the Code key and enter 10 (Fine)
or 11 (Coarse).

Code

Voltage

Press the Left/Right key repeatedly to
move the cursor to Voltage, and use the
numerical and unit keys to enter the
value.

195.00

2.00 Vac

kHz

LCR-8000G Series User Manual

66

66

66

66

Single-Step Test Run

Run in Absolute mode

1. Press F5 to select Absolute

measurement.

F 5

2. Use the Left/Right key to move the

cursor to Hi/Lo value for editing.

Hi

Lo

20.0mF

0.00mF

3. Use the numerical keys

and unit keys to enter the
value. The editing value
appears at the bottom left
corner of the display.

Range
Speed Med

Auto

Lo Lim: 1.5_

Example
1.2mΩ

m

Enter

Backspace

All clear

Clear

Increase

Decrease

Hi and Lo values are automatically swapped if
necessary

Hi and Lo Swapped

4. The display updates the Hi/Lo result

immediately. The result is pass if the bar stays
in the central area. The buzzer sounds
accordingly.