Index, Settng the input mode, Settng the measurement range – Yokogawa PC-Based MX100 User Manual
Page 33: Settng the measurement span
2-19
IM MX180-01E
Integrat
on Mon
tor
3
2
1
4
5
App
Index
2.4 Settng the Measurement Condtons (Settng
the Measurement Channels)
Procedure
Turn ON/OFF collectively
*3
When making the settings
the same as the first item
*3
Reset to default
*3
To copy
*3
*3 Applied to the selected range by dragging the cursor.
Applied to all lines if a range is not selected.
*1 Excluding Tag No. and Tag comment
*2 Cannot be used when Mode is set to RRJC
Record check box
Icon of the attached modules
Point to the icon to display information
about the module
Click the icon to select the channels of
the module
(gray background and red characters)
Monitor check box
Select the input mode
If changed, the Range setting and
others to its right are initialized
*1
Select the measurement range
If changed, the Span setting and
others to its right are initialized
*1
Minimum/Maximum value of span
The Use check box for Scale
*2
Decimal point position of the scale
*2
Maximum/Minimum values of the scale
*2
Click here
Measurement channel tab
1.
Click Channel to show the Channel setup screen.
2.
Click Meas. Channel tab.
Settng the Measurement Channels for Recordng and Montorng
3.
Select Record check boxes of the channels to record.
4.
Select the Monitor check boxes of the channels to monitor.
Settng the Input Mode
5.
Select the input mode from the Mode list box.
Settng the Measurement Range
6.
Select the measurement range from the Range list box.
Settng the Measurement Span
7.
Click the Min box or Max box under Span and enter the minimum or the maximum
value of the span.