background image

4-30

IM MX100-01E

External Dimensions

Unit: mm

57

13

1

150.8

If not specified, the tolerance is ±3%. However, in cases of less than 10 mm, the tolerance is ±0.3

mm.

Setting Value of Span and Preset, and Specified Value of User Output

PWM output setting value

span and preset value

Specified Value of User Output

(count)

0.000%

0

20.000%

20000

40.000%

40000

60.000%

60000

80.000%

80000

100.000%

100000

Output Span Setting

Span setting data when setting transmission output

Target output [%]

0.000

50.000

100.000

PC data*

0

50000

100000

*

PC data refers to internal data between the PC and the MX100 main unit.

Handling Abnormal Data

Types of Abnormal Data

Output Values

Abnormal data upon startup

Preset value or previously held value can be selected

Data upon error occurrence

Preset value or previously held value can be selected

When input channels differ

Preset value or previously held value can be selected

+OVER

Duty 100.000% output

–OVER

Duty 0% output

±OVER determination
For command output, ±OVER determination is performed on the PC, and if the limit

value is exceeded, it is clipped at that limit value. For retransmission output, OVER is
determined by the MX100 main unit.

±OVER conditions
• When duty exceeds 0.000-100.000%
• When the input channel is ±OVER in the case of transmission output