10 counting pulses (/pm1 option), 10 counting pulses (/pm1 option) -17, 10 countng pulses (/pm1 opton) – Yokogawa Button Operated MV2000 User Manual
Page 97
3-17
IM MV1000-01E
Measurement Channels and
Alarms
1
2
3
4
5
6
7
8
9
10
11
12
13
App
Index
3.10 Countng Pulses (/PM1 opton)
This section explains how to use computation channels to count pulses that are received
from pulse input terminals.
For an explanation of this function, see section 1.2.
Dsplay
Press
MENU and then select > Menu tab > Math channel > Calculaton expresson,
Alarm.
Settngs
• Frst-CH, Last-CH
Select the target channels.
• Math range > Math On/Off
Select
On.
• Math range > Calculaton expresson
You can use the following variables in equations.
Q01 to Q08: The number of pulses per second.
P01 to P08: The number of pulses per scan interval.
* The numbers 01 to 08 refer to the pulse input terminal numbers.
For computation channel configuration instructions, see section 10.1.
There are examples on the next page to help explain configuration options.