• Event Data

• Sample rate

Select the data recording interval. Use the table under “Data length” for reference.

• Mode

Settng

Descrpton

Free

Records data continuously.

Single

Records data when a trigger condition is met.

Repeat

Records data whenever a trigger condition is met.

• Data length

Set the size of recorded data files. Recorded data is divided into files of the size

specified here. The data lengths that you can set here vary depending on the
Sample rate setting.

Sample rate

1

25ms

2

125ms

250ms

500ms

1s

Selectable data
lengths

10 min to 4 h

10 min to 1
day

10 min to 2
days

10 min to 3
days

10 min to 7
days

Sample rate

1

2s

5s

10s

30s

1mn

Selectable data
lengths

10 min to 14
days

10 min to 31
days

10 min to 31
days

1 h to 31 days 1 h to 31 days

Sample rate

1

2mn

5mn

10mn

Selectable data
lengths

1 h to 31 days

1 h to 31 days

1 h to 31 days

1 You cannot choose an interval that is faster than the scan interval.
2 Only available on high-speed input models of the MV.

• Pre-trgger

Select the amount of data before each trigger activation that you want to record.

You can select 0, 5, 25, 50, 75, 95, or 100% of the set Data length. If you do not
want to record any data before trigger activations, choose

0%.

• Trgger sgnal > Key

To activate a trigger with key operations, select

On.

Note

• You can activate triggers with the event action function (see section 7.1 for details).
• If a trigger condition is met when the START/STOP key is pressed, recording will begin.