Wrng to the Power Termnal (f the power supply suffx code s -2)

When Usng an AC Adapter

• Precautons to Be Taken Whle Connectng the Power Supply

Make sure to follow the warnings below when connecting the power supply. To prevent

electric shock and damage to the MV, observe the following warnings.

WARNING

• To prevent electric shock, make sure that the power source is turned OFF.
• Only use the power cord that YOKOGAWA provides for use with the MV.
• Confirm that the power source voltage matches the specifications of the AC

adapter before connecting the power cord.

• When you do not plan on using the MV for a while, remove the AC adapter cord

from the AC outlet.

• Only use a YOKOGAWA AC adapter.
• Do not place objects on top of the AC adapter or power cord, and keep them

away from heat sources.

• When removing the plug from the power outlet, do not pull on the cord. Pull

from the plug. If the power cord is damaged, contact your nearest YOKOGAWA
dealer.

Use a power supply that meets the following conditions:

Item

Condton

Rated supply voltage

100 to 240 VAC

Operating supply voltage

range

90 to 264 VAC

Rated supply frequency

50/60 Hz

Power supply frequency range 48 to 62Hz
Maximum power consumption

MV1000: 45 VA (100 V), 60 VA (240 V)
MV2000: 65 VA (100 V), 90 VA (240 V)

• Connecton Procedure

1.

Check that the power switch is OFF.

2.

Connect the power cord and the protective ground cord to the power terminal.

Use a round crimp-on lug (designed for 4-mm screws) with an insulation sleeve.
The appropriate tightening torque for the screws is 1.4 to 1.5 N/m.

Power cord

Functional ground terminal

Protective

grounding cord

Note

Do not wire the protective grounding

cord to the functional ground terminal.

3.

Attach the power terminal cover (transparent), and fasten it with screws.