beautypg.com

Yokogawa Button Operated MV2000 User Manual

Page 118

background image

4-18

IM MV1000-01E

4.8 Loadng and Dsplayng Measured Data from

External Storage Meda

This section explains how to display the waveforms of display and event data that have
been saved in binary format to external storage media. Loaded data will be displayed on
the historical trend display.

For historical trend display operating instructions, see section 5.3.

Procedure

• Loadng a Fle

1.

To access the display:

Press

MENU and then select Fle tab > Load dsplay data or Load Event data.

Press the

CF or USB soft key

*

and then

DISP/ENTER.

* When using a CF card and USB flash memory.

2.

Use the arrow keys to select a directory, and then press

DISP/ENTER. The files in

the directory will appear in a list.

/ is the root directory.

3.

Select a file using the arrow keys, and then press

DISP/ENTER.

The MV loads the file and displays its historical trend.

Note

• The extension for display data files saved in binary format is .DAD. The extension for binary

event data is .DAE.

• For details on using the Sort soft key, see section 4.7.