Generation settings – Teledyne LeCroy SAS Suite User Manual User Manual
Page 255

SASSuite User Manual
Version 6.25
LeCroy Corporation
245
Generation
Settings
Setting
Default
Value Description
Global Settings
GenerationMode
>>>>>
Generation Mode - must be defined or no
generation will take place. Possible Values:
GEN_MODE_SATA_HOST
GEN_MODE_SATA_DEVICE
GEN_MODE_SAS_INITIATOR
GEN_MODE_SAS_TARGET
Default Value: GEN_MODE_ERROR -
undefined mode
SSC
0
Spread Spectrum Clocking mode for SATA.
Can only be set outside Generation block.
MultiSpeedMode
0
When set, the change of speed within
Generation block is allowed with following
syntax: set Speed = LINK_SPEED_1_5G /
LINK_SPEED_3G.
Output Disable
0
This very poorly named register bit forces the
Trainer to output data. It is a little like the
output_on script command except that its
effect cannot be undone for the duration of the
script. If this is turned on, none of the
out-of-band commands will work, as the output
enable is forced on.
AutoMode Settings
AutoOOBMode
0
When set, the generator will go through the
stages of bringing up the link automatically,
including waiting for and responding to the
device or host it is connected to.
AutoHoldMode
0
When set, the generator will respond
automatically to Hold requests. Not supported
for version 1.1 (reserved).
AutoDMAT
0
When set, the generator will respond
automatically to DMAT requests. Not
supported for version 1.1 (reserved).
AutoHandshake
0
When set, the generator will respond
automatically to TBD commands. Not
supported for version 1.1 (reserved).