Sequence Trigger
Sequence triggers can be set to be performed on signals. The options are:
Arm on
Signals ‐ Click the link to open the DDR Select Signals dialog (see
.)
No Arm
Trigger on
Signals ‐ Click the link to open the DDR Select Signals dialog (see
.)
Trigger After ‐ specified (nck)
Reset Arm
Never
Signals ‐ Click the link to open the DDR Select Signals dialog (see
.)
After ‐ specified (nck)
Figure 2.32: Sequence Trigger Settings
Note:
Hold mouse over fields to display tooltips.
The Sequence Trigger feature provides a powerful triggering engine which allows for
defining the trigger at the signal level with arm and roll‐back condition. You can define
the following trigger conditions:
Trigger on any signal transition
Trigger on combination of signals that make a specific command
Trigger on sequence of conditions
Some custom violation detection sequences
The advance trigger has three major conditions:
Arm condition: This condition is used to define condition before trigger.
Reset‐Arm condition: This condition causes resetting of the Arm condition.