V10 - t RFC REFRESH to a Valid Command

Defines the minimum interval between Refresh and the next valid command to the same 
bank. The table outlines the minimum interval while the maximum (between two refresh 
commands) is defined by 9 × Refresh Interval (tREFI).

5.1.11

V11 - tREFI REFRESH Interval

A Refresh command needs to be issued every tREFI interval and a maximum of 8 Refresh 
commands can be postponed during SDRAM operation. Thus, in the event 8 Refresh 
commands are postponed in a row, the maximum interval between two Refresh 
commands would never exceed 9 × tREFI. After exiting Self‐Refresh Mode with one or 
more Refresh commands postponed, additional Refresh commands may be postponed to 
the extent that the total number of postponed Refresh commands (before and after the 
Self‐Refresh) will never exceed eight. During Self‐Refresh Mode, the number of 
postponed or pulled‐in REF commands does not change.

5.1.12

V12 - tRTR READ to READ delay (DDR3 - same rank) (DDR4 - same bank
group)

Defined as the interval between a single READ command and another l READ to the same 
rank and the same DIMM. This is calculated based on the CAS to CAS delay (tCCD) which 
is a minimum of 4 CKs for all speed bins. 

5.1.13

V13 - tdrRTR READ to READ delay (different rank - same DIMM)

Defined as the interval between a single READ command and another READ to a different 
rank within the same DIMM. Read bursts to a different rank are based on the CAS to CAS 
delay (tCCD). Timing between commands to a different rank or DIMM should be vendor 
specified.

5.1.14

V14 - tddRTR READ to READ delay (different DIMM)

Defined as the interval between a READ command and another READ to a different 
DIMM. Timing between commands to a different rank or DIMM should be vendor 
specified.

Speed 
Grade

800

1066

1333

1600

1866

Min 
(ns)

90 

110

160

300

350

Speed 
Grade

Case Temp

800

1066

1333

1600

1866

Min (μs)

0 °C ≤ TCASE ≤ 85 °

7.8 

7.8 

7.8 

7.8 

7.8 

Min (μs)

85 °C < TCASE ≤ 95 °C

3.9

3.9

3.9

3.9

3.9