Kibra DDR Protocol Analyzer User Manual

61

Recording Options Setup

  Teledyne LeCroy

Command Trigger

Triggers can be performed on the following commands:

ACT ‐ Activate

PRE/PREA ‐ Precharge/Precharge All

PDE ‐ Power Down Entry

PDX/SRX ‐ Power Down Exit/Self‐Refresh Exit

MRS[0‐6] ‐ Mode Register Setting. To select specific fields of the MRS command 
use the Sequence Trigger to define the desired signals.

REF ‐ Refresh

ZQCL/ZQCS ‐ ZQ Calibration Long/ZQ Calibration Short

SRE ‐ Self‐Refresh Entry

Figure 2.28: Command Trigger Settings UDIMM and SOUDIMM Selected for DDR4

Note:

Hold mouse over fields to display tooltips.

RCW/BCW Commands Trigger

The Kibra unit provides for triggering on RCW (Register Control Word)/BCW (Buffer 
Control Word) commands. Because these commands are available only on RDIMM/
LRDIMM modules, you should select the correct memory type from RDIMM, LRDIMM or 
SORDIMM to activate. Once one of these is selected, the RCW/BCW commands trigger is 
available in the Advanced Triggers tab. The BCW commands are available only in DDR4 
LRDIMM modules. 

Figure 2.29 on page 62

 shows RCW trigger option in DDR3 and 

Figure 2.30 on page 62

 shows RCW/BCW commands trigger on DDR4.