Recording Options Setup
Teledyne LeCroy
Command Trigger
Triggers can be performed on the following commands:
ACT ‐ Activate
PRE/PREA ‐ Precharge/Precharge All
PDE ‐ Power Down Entry
PDX/SRX ‐ Power Down Exit/Self‐Refresh Exit
MRS[0‐6] ‐ Mode Register Setting. To select specific fields of the MRS command
use the Sequence Trigger to define the desired signals.
REF ‐ Refresh
ZQCL/ZQCS ‐ ZQ Calibration Long/ZQ Calibration Short
SRE ‐ Self‐Refresh Entry
Figure 2.28: Command Trigger Settings UDIMM and SOUDIMM Selected for DDR4
Note:
Hold mouse over fields to display tooltips.
RCW/BCW Commands Trigger
The Kibra unit provides for triggering on RCW (Register Control Word)/BCW (Buffer
Control Word) commands. Because these commands are available only on RDIMM/
LRDIMM modules, you should select the correct memory type from RDIMM, LRDIMM or
SORDIMM to activate. Once one of these is selected, the RCW/BCW commands trigger is
available in the Advanced Triggers tab. The BCW commands are available only in DDR4
LRDIMM modules.
shows RCW trigger option in DDR3 and