beautypg.com

Timing violation trigger – Teledyne LeCroy Kibra DDR User Manual

Page 54

background image

Teledyne LeCroy

Recording Options Setup

52

 

 

Kibra DDR Protocol Analyzer User Manual

Timing Violation Trigger

By default, the software will display all violation triggers in the Timing Violation Trigger 
window. You can select subsets of these trigger events from the drop down menu. 

The following categories are available (see 

Figure 2.19 on page 52

).

DRAM Operations

Read/Write Commands

Low Power States

Initialization Commands

IMPORTANT! To use the JEDEC specified values that match the user defined parameters in Memory 

Controller configuration, click the Refresh Timing Violation Symbol Values button 

 

(see figure below) to apply that set of values to all the entries in this section. They can be 
modified after this action, if desired.

Below is the list of timing violations the user should set manually in Recording Options as 
these cannot be automatically calculated based on DIMM selection parameters:

V13: READ to READ (different rank, same DIMM) < tDRRTR

V14: READ to READ (different DIMM) < tDDRTR

V16: READ to WRITE (different rank, same DIMM) < tDRRTW

V17: READ to WRITE (different DIMM) < tDDRTW

V19: WRITE to READ (different rank, same DIMM) < tDRWTR

V20: WRITE to READ (different DIMM) < tDDWTR

V22: WRITE to WRITE (different rank, same DIMM) < tDRWTW

V23: WRITE to WRITE (different DIMM) < tDDWTW

Note:

The default value is 0, which results in the timing violation NOT being used for triggering or error 

analysis.

Figure 2.19: Timing Violation Trigger Settings for DDR3-800

Trigger on JEDEC command timing violations are captured for DRAM Operations, Read/
Write Commands, Low Power States and Initialization Commands. Select any of these