IAI America PSEP User Manual
Page 50
![background image](/manuals/350313/50/background.png)
44
/
2.
Wiring
2.4.4 Connection of PIO
Conduct the connection of I/O to the controller is to be carried out using the dedicated I/O cable. The
cable length is shown in the model code of the controller. Please check the controller model code.
There are 2m for standard, 3m and 5m as an option. 10m is also applicable at maximum if purchased
separately. [Refer to “1.1.5. How to read the model]
Also, the end of the cable harness to be connected to the host controller (PLC, etc.) is just cut and no
treatment is conducted so the wiring layout can be performed freely.
0RGHO&%$36(33,2ƑƑƑÂÂÂ)RU$6(3&36(3&
ƑƑƑVKRZVWKHFDEOHOHQJWK/([DPSOH 2m)
Ɣ 3,2&RQQHFWRU
Applied Connector
55959-1030
Manufactured by MOLEX
Connector Name
I/O
PIO Connector
Connection Cable
Dedicated Cable [refer to (3) in this
section.]
Enclosed in this controller
L
10
2
1
9
0RGHO&%$36(3:3,2ƑƑƑÂÂÂ)RU$6(3&:36(3&:
ƑƑƑVKRZVWKHFDEOHOHQJWK/([DPSOH 2m)
L
10
2
1
9
Connector
51353-1000 (Manufactured by MOLEX)
No.
Color
Signal Name
CB-APSEP-PIO
ƑƑƑ
CB-APSEPW-PIO
ƑƑƑ
1
BR
BR
24V
2
RD
BR, WT
0V
3
OR
RD
IN0
4
YW
RD, WT
IN1
5
GN
YW
IN2
6
BL
YW, WT
IN3
7
PL
GN
OUT0
8
GY
GN, WT
OUT1
9
WT
BK
OUT2
10
BK
BK, WT
OUT3