23

/

6SHFL¿FDWLRQV&KHFN

Item

ASEP

PSEP

DSEP

Forcibly releasing of
electromagnetic brake switch

None
Supply 24V DC 150mA to BK on power connector when
a compulsory release of the brake is required.

None
Brake cannot
be compulsorily
released.

Dielectric withstanding voltage/
resistance

500V DC 10M

7

Protection Function against
Electric Shock

Class I basic insulation

Cooling method

Natural air-cooling

Environment Use environment

Pollution degree 2

Surrounding air
temperature

0 to 40

oC

Surrounding humidity 85% RH or less (non-condensing)
Surrounding
environment

[Refer to 1.5 Installation Environment.]

Surrounding storage
temperature

-25 to 65

oC (Battery to be stored at 40oC or lower)

Usage altitude

1000m or lower above sea level

Protection code

IP20: Equivalent to IP53 (Option) with the installation of the dust-proof cover

Vibration durability

Frequency 10 to 57Hz / Swing width : 0.075mm
Frequency 57 to 150Hz / Acceleration : 9.8m/ S

2

XYZ Each direction Sweep time : 10 minutes Number of sweep : 10 times

Weight

130g or less, 160g or less (INC-Dust-proof type)

External dimensions

30W × 100H × 66.2D (mm)

Note 3: Position data and parameters are written to EEPROM. The limitation for the reload is

about 100,000 times. Take the greatest care.

Do not turn the power off during the rewriting process.

As a

24V DC power supply, select the power

VXSSO\RIWKH³SHDNORDGVXSSRUW´VSHFL¿FDWLRQ
RURQHZLWKVXI¿FLHQWFDSDFLW\
In the case that the capacity margin is not
VXI¿FLHQWYROWDJHPLJKWEHGURSSHGLQ
a moment. Especially, the power supply
equipped with remote sensing reacts to the
transient voltage drop and raises the voltage
for adjustment, which may result in overvoltage
error.

Ö

(Note 1) The current reaches its maximum level when the servo-motor

H[FLWLQJSKDVHLVGHWHFWHGZKLFKLVWREHSHUIRUPHGLQWKH¿UVW
servo-motor turning ON processing after the power injection.
(Normal: Approx. 1 to 2sec, Max.: 10sec)

(Note 2) The excitation detection operation is performed after the power

is input. In such a case, the current becomes maximum.
(normally 100msec)
+RZHYHUDFXUUHQWRIDSSUR[$ÀRZVLIWKHPRWRUGULYLQJ
power is turned on again after its shutdown. (for approx. 1 to
2msec)