23
/
6SHFL¿FDWLRQV&KHFN
Item
ASEP
PSEP
DSEP
Forcibly releasing of
electromagnetic brake switch
None
Supply 24V DC 150mA to BK on power connector when
a compulsory release of the brake is required.
None
Brake cannot
be compulsorily
released.
Dielectric withstanding voltage/
resistance
500V DC 10M
7
Protection Function against
Electric Shock
Class I basic insulation
Cooling method
Natural air-cooling
Environment Use environment
Pollution degree 2
Surrounding air
temperature
0 to 40
oC
Surrounding humidity 85% RH or less (non-condensing)
Surrounding
environment
[Refer to 1.5 Installation Environment.]
Surrounding storage
temperature
-25 to 65
oC (Battery to be stored at 40oC or lower)
Usage altitude
1000m or lower above sea level
Protection code
IP20: Equivalent to IP53 (Option) with the installation of the dust-proof cover
Vibration durability
Frequency 10 to 57Hz / Swing width : 0.075mm
Frequency 57 to 150Hz / Acceleration : 9.8m/ S
2
XYZ Each direction Sweep time : 10 minutes Number of sweep : 10 times
Weight
130g or less, 160g or less (INC-Dust-proof type)
External dimensions
30W × 100H × 66.2D (mm)
Note 3: Position data and parameters are written to EEPROM. The limitation for the reload is
about 100,000 times. Take the greatest care.
Do not turn the power off during the rewriting process.
As a
24V DC power supply, select the power
VXSSO\RIWKH³SHDNORDGVXSSRUW´VSHFL¿FDWLRQ
RURQHZLWKVXI¿FLHQWFDSDFLW\
In the case that the capacity margin is not
VXI¿FLHQWYROWDJHPLJKWEHGURSSHGLQ
a moment. Especially, the power supply
equipped with remote sensing reacts to the
transient voltage drop and raises the voltage
for adjustment, which may result in overvoltage
error.
Ö
(Note 1) The current reaches its maximum level when the servo-motor
H[FLWLQJSKDVHLVGHWHFWHGZKLFKLVWREHSHUIRUPHGLQWKH¿UVW
servo-motor turning ON processing after the power injection.
(Normal: Approx. 1 to 2sec, Max.: 10sec)
(Note 2) The excitation detection operation is performed after the power
is input. In such a case, the current becomes maximum.
(normally 100msec)
+RZHYHUDFXUUHQWRIDSSUR[$ÀRZVLIWKHPRWRUGULYLQJ
power is turned on again after its shutdown. (for approx. 1 to
2msec)