7. PLC Timer Setting

Do not have the PLC timer setting to be done with the minimum setting.

Setting to “1” for 100msec timer turns on at the timing from 0 to 100msec while 10msec timer

from 0 to 10msec for some PLC.

Therefore, the same process as when the timer is not set is held and may cause a failure such

as the actuator cannot get positioned to the indicated position number in Positioner Mode.

Set “2” as the minimum value for the setting of 10msec timer and when setting to 100msec, use

10msec timer and set to “10”.

8. Cautions when turning Servo on (for ASEP/PSEP)

The magnetic pole phase detection may not be performed normally if the servo is turned on near

the mechanical end, and may cause such problems like an abnormal operation, magnetic pole

QRWEHLQJGH¿QHGRUHOHFWURPDJQHWLFGHWHFWLRQHUURU

Put it away from the mechanical end when turning the servo on.

9. Make sure to follow the usage condition, environment and

VSHFL¿FDWLRQVRIWKHSURGXFW

Not doing so may cause a drop of performance or malfunction of the product.