beautypg.com

8 boot loader updates – Datamax-O'Neil I-Class Operator’s Manual User Manual

Page 93

background image

I-Class

83

5.8 Boot Loader Updates


The printer stores its Boot Loader program in Flash memory on the main logic card. As
available, updates can be found on our web site at

ftp://ftp.datamax-oneil.com

and then

installed in the printer.

WARNING

If power is lost while UPGRADING SOFTWARE is displayed, the printer will
become non-functional and will require factory programming or a main logic

card.


Before updating, identify the current program version by printing a Configuration Label (see
Section 4.3.2). Compare that version string to those available from our web site then
download the desired file onto your computer’s hard drive. Follow the steps below to update

the version:

Boot Loader Update Procedure

Step

Displayed Message

Action

Comment(s)

1 READY

Using the DOS copy

command (where
“filename” is the

program to be loaded
and “lpt1” is the
selected interface

port), enter the
following:


copy filename lpt1:

As an example, this would be

entered as:

copy boottb99_1101.bs lpt1

(Where “lpt1” can differ to

include another port, as
equipped.)


The Ready Indicator will flash
as data is received.

2

UPGRADING SOFTWARE

No action required.

The new program is being

stored and verified.

3

4212
11.05 03/26/2008

No action required.

The printer has reset

automatically.

4

READY

No action required.

The new application is now
running.

Note: If UNCALIBRATED is

displayed, see Section 5.2.

Note: If the update failed, press and hold the PAUSE and TEST Keys (see Section 4.1)

while turning ON the printer. After SEND SOFTWARE is displayed, release the