Datamax-O'Neil I-Class Operator’s Manual User Manual
Page 73

I-Class
63
Standard Calibration (continued)
Step
Action
Displayed Message
Comment
7
Proceed according to your
media:
Die-cut – remove a label
from the backing
material then place the
backing in the sensor.
Adjust the Sensor Eye
Mark over the center of
the backing.
Notched – load media in
the printer then adjust
the Sensor Eye Mark
over the center of the
notch.
Reflective – load media
in the printer (black
mark facedown) then
adjust the Sensor Eye
Mark over the center of
the black mark.
Continuous – go to Step
8.
Press any key to continue.
SCAN BACKING
PRESS ANY KEY
Or, for reflective media:
SCAN MARK
PRESS ANY KEY
See Section 3.3 for
sensor positioning
details.
This sets the backing,
gap, or mark value where
“yyy” is the current
sensor reading.
Note: Never position
the sensor over a
perforation when
sampling.
Note: Do not move the Media Sensor after it has been positioned.
Step
Action
Displayed Message
Comment
8
Position the media (and
backing, if any) under the
sensor then press any key
to continue.
SCAN PAPER
PRESS ANY KEY
This sets the paper value,
where “yyy” is the
current sensor reading.
Note: If using
preprinted media, ensure
the label area under the
Sensor Eye Mark is free
of text, graphics, or
borders.