beautypg.com

3 reset methods – Datamax-O'Neil I-Class Operator’s Manual User Manual

Page 80

background image

70

I-Class

Advanced Entry Calibration (continued)

Step

Action

Displayed Message

Comment

17

After all entries have been
made, press the

Key

to back out of the menu and
then press the

Key

to save the settings and
return to the Ready Mode.

SAVE CHANGES?

ENTER KEY = YES

From READY, press the

FEED Key to advance to
the next label TOF.

Note: If the Advanced Entry Calibration fails, enter MEDIA SETTINGS / CALIBRATION /

ADVANCED ENTRY / SENSOR GAIN and lower the selected Gain Number by one.

Select the new Gain Number then save the changes and exit the menu. Retest
your media. If unsuccessful, repeat the procedure until a usable gain is
obtained.



5.3 Reset Methods



There are three reset methods, each with a different affectivity. Proceed according to the

desired result:

5.3.1 Soft Reset

To clear any temporary host settings, press and hold the CANCEL Key for approximately
four seconds.

5.3.2 Level One Reset

To return the factory default settings or (if saved) a Factory Setting File, turn OFF the
printer. Press and hold the PAUSE and CANCEL Keys while turning ON the printer and until

the SYSTEM RESET message flashes.

Note: The same as selecting SET FACTORY DEFAULTS; see Section 4.2.5.

5.3.3 Level Two Reset

To return the firmware default settings and clear all parameters, turn OFF the printer. Press
and hold the PAUSE, FEED, and CANCEL Keys while turning ON the printer and until the

SYSTEM RESET message flashes.

Note: Calibration is required; see Section 5.2.