beautypg.com

Datamax-O'Neil I-Class Operator’s Manual User Manual

Page 40

background image

30

I-Class

Printer Options (continued)

Menu Item

Details

BARCODE COUNT

Specifies a number of bar codes per label and
generates a fault when the number present is incorrect,

where:

00 (0 - 99)

Sets the number of bar codes to count, where 00 (Auto
Mode) allows a variable number.

Note: If bar codes are bitmaps, enter the minimum

number to be read on each label (check your
software application if questioning the bar
code generation method).

MIN READABLE HEIGHT

Ensures bar code integrity by setting a minimum

distance for identical decodes, where:

DISABLED

Uses REDUNDANCY LEVEL to ensure bar code integrity.

1/16 – ½ in
(1.5–12.5mm)

Sets a read distance requirement to pass the bar code

(e.g., ¼ requires .25 inches to be readable).

Note: This distance should not exceed 50% of the

measured bar code height.

REDUNDANCY LEVEL

Ensures bar code integrity by specifying a consecutive

number of identical decodes, where:

READ BARCODE 3X

Sets a valid read count requirement (1X – 6X) to pass

the bar code (e.g., 3X must return three identical
decodes).

Note: High redundancy rates and fast print speeds

may cause erroneous read failures when
scanning small or multiple bar codes.

AUTO

Uses MIN READABLE HEIGHT to ensure bar code

integrity.

IGNORE NO DATA

Allows an override of data verification, where:

DISABLED

Checks for correct bar code data in the bar code(s).

ENABLED

Ignores the data present in the bar code(s).

SET DEFAULTS

Restores the scanner settings to the default values,

where:

SET FACTORY DEFAULT?
CANCEL KEY = YES

Restores the defaults, or press the ESC Key to keep the

current configuration.