System Settings (continued)

Menu Item

Details

FAULT HANDLING

Determines the label disposition and user action if a
fault occurs, where:

LEVEL

Sets the printer response upon declaration of a fault,

where:

STANDARD

Stops printing and declares a fault. Then, following

correction of the problem, the FEED Key must be

pressed to clear the fault and reprint the label in
process.

VOID AND RETRY

Actions depend upon the RETRY COUNT:

If the count has not been exceeded, VOID is printed

on the failed label and reprinting automatically
occurs;

If the count has been exceeded, printing stops and a
fault message is displayed. Then, following correction

of the problem, the FEED Key must be pressed to
clear the fault and reprint the label in process; or,

If the CANCEL Key is pressed, reprinting is optional:

press NO to reprint; or, press YES to cancel the
reprint (and press YES again to cancel the batch.)

Note: Linear Scanner or RFID required.

DELAYED SCAN FAULT

Increases throughput when bar codes reside near the

trailing edge of the label (in the direction of FEED).

Notes: (1) Linear Scanner or RFID required.

(2) If unreadable, the fault will occur after

the next label prints;

(3) The label immediately following a

faulted label is not scanned for errors; and,

(4) VOID AND RETRY and REPRINT are
automatically disabled; the job can only be

cancelled.

VOID RETRY & CONT.

VOID is printed on a faulted label, with reprint

attempts occurring automatically, until the RETRY
COUNT has been exceeded and then that label will be

skipped (discarded) and printing will continue to the
next label in queue.

Note: Linear Scanner or RFID required.

NO REPRINT

Printing stops and a fault message is displayed.
Following correction of the problem, the FEED Key

must be pressed to clear the fault.