beautypg.com

Datamax-O'Neil I-Class Operator’s Manual User Manual

Page 100

background image

90

I-Class

Warning Messages (continued)

Warning Messages

Displayed Message

Description

Action(s)

LOW VOLTAGE

The printer has detected
a low operating voltage.

Possible low or fluctuating line
voltage level – Try moving
the printer to another AC

outlet; if the condition
persists, call for service.

If printing black over more
than 50% of the total label

area, try reducing the HEAT
setting or the size of the
black area.

RTC RAM FAILURE

The printer was unable to
save settings in

permanent memory.

Possible faulty main logic card. If
the condition persists, call for

service.

TEMPERATURE PAUSE

A high printhead

temperature has been
detected.

No action required. Printing will

resume after the printhead
cools.


Fault Messages:


Fault Messages indicate a problem and appear on the LCD with the highest priority. If more

than one fault is detected, messages cycle. (Alternate messages may occur when
downloading font, firmware, or Boot Loader files.)

Note: To return operation after a fault occurs, the fault must be corrected and the

FEED Key pressed.

Fault Messages

Displayed Message

Description

Action(s)

24V OUT OF TOLERANCE

The printer has detected

a drop in the 24-volt
power supply.

Try cycling the printer power OFF

and ON. If the fault does not

clear, call for service.

ADC FAULT

The printer has detected

an analog to digital circuit
converter failure.

Try cycling the printer power OFF

and ON. If the fault does not

clear, call for service.