beautypg.com

Datamax-O'Neil I-Class Operator’s Manual User Manual

Page 44

background image

34

I-Class

Printer Options (continued)

Menu Item

Details

RETRY ATTEMPTS

Sets the number of retry attempts, where:

3 (0 - 9)

Is the retry count before a fault is declared.

AUTO DETECT TAG

Allows the printer to establish the tag to transducer

distance setting. CALIBRATING RFID will appear as
media is scanned for the tag location. Upon completion,

the media will be retracted to the TOF position with the
positioning results (along with a brief SUCCESS or
FAILURE message).

SET DEFAULTS

Allows the RFID default values to be restored, where:

YES

Restores the default settings.

NO

Exits the menu item without changing the current

settings.

GPIO PORT

Controls the GPIO operation, where:

GPIO DEVICE

Sets the GPIO option to work with a specific device

type, where:

APPLICATOR

Enables parameters for related label applicator
functions:

Completion upon last SOP, de-asserts Data Ready

(DRDY);

FEED allowed at any time; and,

DRDY upon PAUSE.

APPLICATOR2

Enables parameters for alternate label applicator
functions:

Completion upon 1 msec. overlap of Data Ready

(DRDY) and End of Print (EOP);

DRDY signal end inhibits FEED; and,

De-asserts DRDY upon PAUSE or FAULT.

BARCODE VERIFIER

Enables the GPIO Port to work with a bar code verifier.

DISABLED

Disables the option.