Advanced Entry Calibration (continued)

Step

Action

Displayed Message

Comment

7

Press the

Key.


Place the label under the

Sensor Eye Mark, and then
lower the printhead

assembly.

GAIN TRAN

*00 <0 - 31>


Or, for reflective media:

GAIN REFL

*00 <0 - 31>

See Section 3.3 for
sensor positioning
details.


If using preprinted

media, ensure the label
area under the Sensor

Eye Mark is free of text,
graphics, or borders.

8

Use the

Key to scroll

to the 00 GAIN setting and
then press the

Key.


Record the sensor reading

as a Label Value in a table
similar to the one shown
below.

GAIN TRAN

*00 <0 - 31>

Or, for reflective media:

GAIN REFL

*00 <0 - 31>

Selection is denoted by
an asterisk (*).


The sensor reading

equals the “yyy” value.

Note: Never position

the sensor over a
perforation when
sampling.


Sampling Table

Gain

Number

Label

Value

TOF

Value

Difference

Value

00 255
01

02

31

Step

Action

Displayed Message

Comment

9

Press the

Key to

increment the Gain Number
then press the

Key

and record the resulting
Label Value.


Repeat this step for each of

the remaining Gain
Numbers (01-31).

GAIN TRAN

*31 <0 - 31>

Or, for reflective media:

GAIN REFL

*31 <0 - 31>