5.2.2 Advanced Entry Calibration


Advanced Entry is the alternate calibration method for special-case media types. In the

procedure, sensor readings for the label and TOF values are taken using different sampling
algorithms. From this compiled list of values the best algorithm is selected and then used to

generate new readings for manual entry into memory.

Note: Use this method only when Standard Calibration has proven unsuccessful.

With the correct SENSOR TYPE selected (see Section 4.2.2), perform an Advanced Entry
Calibration as follows:

Step

Action

Displayed Message

Comment

1

Turn ON the printer.

UNCALIBRATED

Wait briefly, about six

seconds, for the printer
to initialize.

2

Press the

Key, and

then raise the printhead
assembly.

MENU MODE

MEDIA SETTINGS

You are in MENU MODE.

3

Press the

Key.

MEDIA SETTINGS

MEDIA TYPE

You are in MEDIA

SETTINGS.

4

Press the

Key then

scroll to SENSOR
CALIBRATION.

MEDIA SETTINGS

SENSOR CALIBRATION

Press the

Key to

cancel this procedure.

5

Press the

Key, and

then the

Key.

SENSOR CALIBRATION

ADVANCED ENTRY

Press the

Key to

cancel this procedure.

6

Press the

Key, and

then the

Key.

ADVANCED ENTRY

SENSOR GAIN

You are beginning the

procedure.