Datamax-O'Neil I-Class Operator’s Manual User Manual
Page 61

I-Class
51
Communications (continued)
Menu Item
Details
HEAT COMMAND
Determines how a host software Heat command is
handled, where:
ENABLED
Processes commands normally.
DISABLED
Ignores commands; instead, Heat is controlled via the
menu setting; see Section 4.2.3.
SPEED COMMANDS
Determines how host software Print, Feed, Reverse,
and Slew commands are handled, where:
ENABLED
Processes commands normally.
DISABLED
Ignores commands; instead, the speeds are controlled
via the menu setting; see Section 4.2.3.
TOF SENSING COMMANDS
Determines how host software Gap, Continuous, and
Reflective commands are handled, where:
ENABLED
Processes commands normally.
DISABLED
Ignores commands; instead, Sensor Type is controlled
via the menu setting; see Section 4.2.3.
SYMBOL SET COMMAND
Determines how host Single and Double Symbol Set
commands are handled, where:
ENABLED
Processes commands normally.
DISABLED
Ignores commands; instead, the Symbol Set selection
is controlled via the menu setting; see Section 4.2.5.
CNTRL-CODES (DATA)
Determines how host software Control Codes are
handled, where:
ENABLED
Processes commands normally.
DISABLED
Controls the setting via the menu; see CONTROL
CODES, above.
STX-V SW SETTINGS
Determines how a host software option enable
command is handled, where:
ENABLED
Processes commands normally.
DISABLED
Controls the settings via the menu; see Section 4.2.4.