beautypg.com

Datamax-O'Neil I-Class Operator’s Manual User Manual

Page 61

background image

I-Class

51

Communications (continued)

Menu Item

Details

HEAT COMMAND

Determines how a host software Heat command is
handled, where:

ENABLED

Processes commands normally.

DISABLED

Ignores commands; instead, Heat is controlled via the

menu setting; see Section 4.2.3.

SPEED COMMANDS

Determines how host software Print, Feed, Reverse,
and Slew commands are handled, where:

ENABLED

Processes commands normally.

DISABLED

Ignores commands; instead, the speeds are controlled

via the menu setting; see Section 4.2.3.

TOF SENSING COMMANDS

Determines how host software Gap, Continuous, and
Reflective commands are handled, where:

ENABLED

Processes commands normally.

DISABLED

Ignores commands; instead, Sensor Type is controlled

via the menu setting; see Section 4.2.3.

SYMBOL SET COMMAND

Determines how host Single and Double Symbol Set
commands are handled, where:

ENABLED

Processes commands normally.

DISABLED

Ignores commands; instead, the Symbol Set selection

is controlled via the menu setting; see Section 4.2.5.

CNTRL-CODES (DATA)

Determines how host software Control Codes are
handled, where:

ENABLED

Processes commands normally.

DISABLED

Controls the setting via the menu; see CONTROL

CODES, above.

STX-V SW SETTINGS

Determines how a host software option enable
command is handled, where:

ENABLED

Processes commands normally.

DISABLED

Controls the settings via the menu; see Section 4.2.4.