beautypg.com

7 diagnostics – Datamax-O'Neil I-Class Operator’s Manual User Manual

Page 63

background image

I-Class

53

4.2.7 Diagnostics


The Diagnostics menu contains testing functions:

Menu Item

Details

HEX DUMP MODE

Allows raw code received from the host to print, where:

DISABLED

Executes commands and prints label formats normally.

ENABLED

Prints received data without processing; see Section

6.2.

OPTIONS TESTING

Allows testing of printer options, where:

TEST PRESENT SENSOR

Tests the Present Sensor (and Peel & Present

Mechanism) on demand function, where:

PERFORM TEST
1 TIME

Selects the number of LABEL PRESENTED tests (1, 10,

or 100) to perform, and then displays the results.

TEST CUTTER

Tests the Cutter, where:

PERFORM TEST
1 TIME

Selects the number of cuts (1, 10, or 100) to perform,

and then displays the results.

TEST GPIO

Tests the General Purpose Input Output interface,

where:

MONITOR GPIO INPUT

Displays the logic values for Start of Print (SOP), Feed,
Pause, and Reprint (REPRT) signal inputs. (The values

given below are examples only.)

SOP FEED

PAUSE

REPRT

0 0 0 0

Note: Unconnected lines may assume a zero or one.

MONITOR GPIO OUTPUT

Allows toggling and displays the logic values for End of

Print (EP), Ribbon Low (RL), Service Required (SR),
Media Out (MO), Ribbon Out (RO), Data Ready (DR),

and Output Fault (OF) signal outputs. (The values given
below are examples only.)

EP RL SR MO RO DR OF

1 1 0 1 1 0 0

Note: To change an output signal, cursor over the

displayed state to select and then toggle it,
except Data Ready which cannot be toggled.