beautypg.com

Datamax-O'Neil I-Class Operator’s Manual User Manual

Page 105

background image

I-Class

95

Fault Messages (continued)

Fault Messages

Displayed Message

Description

Action(s)

TOP OF FORM FAULT

The printer could not find
the TOF within the

maximum label length
setting, or TOF occurred in

an unexpected place.

Note: When using

reflective media, this fault
is given for an Out of Stock
condition.

If media is moving:


1) Press the FEED Key. It may be

necessary to re-calibrate the
printer; see Section 5.2.

2) The Media Sensor may be out

of position. Readjust it; see

Section 3.3.

3) The media may not be

properly loaded. Reload

media, ensuring that the
Media Guide is properly
positioned; see Section 3.2.


4) The Leveling Cam may be

improperly adjusted; see
Section 5.4.1.


5) The label may be longer than

the value entered. Check the
Media Settings / Maximum
Label Length; see Section

4.2.2.

6) The Media Sensor may be

obstructed. Check and

carefully remove any
obstruction (labels, paper

dust, adhesive, etc).

If media is not moving:

The printhead assembly may not

be locked.

VERIFIER FAULT

The Verifier could not pass

a bar code.

Note: This is normal

when a bar code is
unreadable.

Simultaneously press the ENTER

and F1 Keys on the Verifier to
clear the fault. If the fault

persists, consult the option’s