Diagnostics (continued)

Menu Item

Details

SENSOR READINGS

Displays A-D sensor values (0 – 255), where:

THR TRAN RIBM 24V 
127 159 093 175

 PS HD RANK
000 254 000

Are the sensor readings, where:

THR = Printhead thermistor sensor;

TRAN = Media sensor when set to Gap or Continuous, or

REFL when to Reflective;

RIBM = Ribbon sensor;

24V = 24 VDC sensor;

PS = Present sensor;

HD = Printhead position sensor; and,

RANK = Printhead ranking resistor.

Note: Readings provided here are examples only.

RIBBON SENSOR LIMITS

Displays the values from the ribbon sensor (when

equipped with the thermal transfer option), where:

RIBBON ADC LOW HIGH
070 104

Are the sensor readings (actual values will vary).




4.2.8 MCL Options

The MCL Options menu contains alternate operating selections:

Menu Item

Details

MCL OPTIONS

Allows the optional MCL (Macro Command Language)
tool suite to accept peripheral input data, where:

MCL AT POWER-UP

Allows MCL operation to begin when the printer is

turned ON, where:

DISABLED

No MCL operation.

MCL LINK MODE

Starts MCL in Link Mode.

MCL PROGRAM MODE

Starts MCL in Program Mode.

START MCL

Starts MCL after exiting the menu.

Note: Consult your MCL provider for details regarding operation and support.