Advanced Entry Calibration (continued)

Step

Action

Displayed Message

Comment

11

Press the

Key to

increment the Gain Number

then press the

Key

and record the resulting

TOF Value.


Repeat this step for each of

the remaining Gain
Numbers (01-31).

GAIN TRAN

*31 <0 - 31>


Or, for reflective media:

GAIN REFL

*31 <0 - 31>

12

From the collected data,
where both the values are

above 20, subtract the
Label Value from the

corresponding TOF Value to
find the Difference Value.

Note the Gain Number of
the largest Difference

Value.

GAIN TRAN

*31 <0 - 31>

Or, for reflective media:

GAIN REFL

*31 <0 - 31>

For example in the table
below, Gain Number 08 is

chosen because it has the
highest Difference Value

(146) where both the
Label and the TOF Values
are above 20.

Sampling Table

Gain

Number

Label

Value

TOF

Value

Difference

Value

00 255

254

1

01 251

240

11

02 241

213

28

03 231

182

49

04 219

150

69

05 212

119

93

06

200 88 112

07

189 58 131

08

178 32 146

09 167

19

N/A

10 156

17

N/A

… …

31 116

14

N/A

Step

Action

Displayed Message

Comment

13

Using the

Key, scroll

to the Gain Number

determined in Step 12, and
then press the

Key.

GAIN TRAN

*08 <0 - 31>

Or, for reflective media:

GAIN REFL

*08 <0 - 31>