Advanced Entry Calibration (continued)
Step
Action
Displayed Message
Comment
11
Press the
Key to
increment the Gain Number
then press the
Key
and record the resulting
TOF Value.
Repeat this step for each of
the remaining Gain
Numbers (01-31).
GAIN TRAN
*31 <0 - 31>
Or, for reflective media:
GAIN REFL
*31 <0 - 31>
12
From the collected data,
where both the values are
above 20, subtract the
Label Value from the
corresponding TOF Value to
find the Difference Value.
Note the Gain Number of
the largest Difference
Value.
GAIN TRAN
*31 <0 - 31>
Or, for reflective media:
GAIN REFL
*31 <0 - 31>
For example in the table
below, Gain Number 08 is
chosen because it has the
highest Difference Value
(146) where both the
Label and the TOF Values
are above 20.
Sampling Table
Gain
Number
Label
Value
TOF
Value
Difference
Value
00 255
254
1
01 251
240
11
02 241
213
28
03 231
182
49
04 219
150
69
05 212
119
93
06
200 88 112
07
189 58 131
08
178 32 146
09 167
19
N/A
10 156
17
N/A
… …
…
…
31 116
14
N/A
Step
Action
Displayed Message
Comment
13
Using the
Key, scroll
to the Gain Number
determined in Step 12, and
then press the
Key.
GAIN TRAN
*08 <0 - 31>
Or, for reflective media:
GAIN REFL
*08 <0 - 31>