beautypg.com

Datamax-O'Neil I-Class Operator’s Manual User Manual

Page 79

background image

I-Class

69

Advanced Entry Calibration (continued)

Step

Action

Displayed Message

Comment

14

a) Place the media in the

sensor. Record the
reading and label it “P”

(paper).

b) Place the backing, notch,

or mark in the sensor.

Record the reading and
label it “G” or “M” (Gap or
Mark).


c) Remove media. Record

the reading and label it
“E” (Empty).

GAIN TRAN

*08 <0 - 31>


Or, for reflective media:

GAIN REFL

*08 <0 - 31>

The samplings using the

selected Gain Number
are taken.

15

Press the

Key, and

then press the

Key.

ADVANCED ENTRY

SENSOR LEVELS

The sensor readings
must be entered into the

printer.

16

Press the

Key.


Using the

Key or the

Key, set the Paper

Sensor Level to the value
determined in the previous

step.

Press the

Key to

select the entry and
advance the menu.

Repeat for the Gap Sensor
Level (or Mark Sensor Level)

and the Empty Sensor Level
entries.

PAPER SENSOR LEVEL

P*198 G*084 E*014

GAP SENSOR LEVEL

P*198 G*084 E*014

EMPTY SENSOR LEVEL

P*198 G*084 E*014


Or, for reflective media:

PAPER SENSOR LEVEL

P*015 M*181 E*213

MARK SENSOR LEVEL

P*015 M*181 E*213

EMPTY SENSOR LEVEL

P*015 M*181 E*213

Selection is denoted by

an asterisk (*).


The displayed message

will change and the
selection will flash to

indicate the next entry.