beautypg.com

Datamax-O'Neil I-Class Operator’s Manual User Manual

Page 60

background image

50

I-Class

Communications (continued)

Menu Item

Details

SET FACTORY DEFAULTS

Returns the NIC to factory-programmed values, where:

SET FACTORY DEFAULTS?
CANCEL KEY = YES

Restores the default settings.

Note:

Press the ESC Key to exit the menu item
without changing the current settings.

HOST SETTINGS

Sets host communication parameters; where:

HOST TIMEOUT

Sets the period that an interface port can be idle before

timeout occurs, where:

10 SEC (1 - 60)

Is the time (in seconds) when downloads timeout, and

that must elapse before alternate port or alternate

parser processing can occur.

CONTROL CODES

Allows changes to the software command interpretation

controls, where:

STANDARD CODES

Sets the following command interpretation codes: Hex

01 = SOH command; Hex 02 = STX command; count-
by = ^; Hex 1B = ESC; Hex 0x0D = Carriage Return

ALTERNATE CODES

Sets the following command interpretation codes: Hex

5E = SOH command; Hex 7E = STX command; count-
by = @; Hex 1B = ESC; Hex 0x0D = Carriage Return

ALTERNATE CODES 2

Sets the following command interpretation codes: Hex
5E = SOH command; Hex 7E = STX command; count-

by = @; Hex 1B = ESC; Hex 0x7C = Carriage Return

CUSTOM CODES

Sets the command interpretation codes as needed,

where:

SOH STX CR CNTBY
5E 7E 0D 40

Are the codes according to your definitions.

FEEDBACK CHARACTERS

Allows the return of printer codes, where:

DISABLED

Does not send feedback characters.

ENABLED

Sends the host a Hex 1E (RS) after each label and a

Hex 1F (US) after each label batch successfully prints.

ESC SEQUENCES

Allows data containing invalid ESC control code

sequences to be processed, where:

ENABLED

Processes commands normally.

DISABLED

Ignores ESC sequences during processing (since some

systems send a “banner” to the printer).

Note: Bitmapped font downloads are disabled.