2 calibration – Datamax-O'Neil I-Class Operator’s Manual User Manual

Page 71

background image

I-Class

61

Prompts and Condition Messages (continued)

Displayed Message

Description

Action

SYSTEM INITIALIZING The power switch has been turned

ON or a reset has occurred.

No action is required.

Wait briefly while the
process completes.

SYSTEM RESET

IN PROGRESS

A reset has occurred.

No action is required.
Wait briefly while the

process completes.

UNCALIBRATED

The Media Sensor is not calibrated. Perform calibration; see

Section 5.2.

WAITING FOR DATA

The SOP signal has been received,
but the printer awaits label data.

Send data from the
host.

WAITING FOR SIGNAL

The printer awaits a SOP signal.

Send the SOP signal

from the applicator to
the GPIO port.

XXXX OF XXXX

PRINTING

A print job is in process, as
indicated by the batch total and

remaining label count.

No action is required.


5.2 Calibration



Calibration ensures label detection. Perform calibration when the UNCALIBRATED is
displayed. Two different methods, Standard and Advanced Entry, are available to calibrate

the printer.

5.2.1 Standard Calibration


Standard Calibration, appropriate for most media types, is a method that allows visual
access to the media sensor for positioning. Displayed sensor readings can also be used to

indicate the best position over the media – helpful when using small, position-critical TOF
notches or marks.