Menu Item

Details

MAX LENGTH COMMAND

Determines how a host software Maximum Label
Length (M) command is handled, where:

ENABLED

Processes commands normally.

DISABLED

Controls the setting via the menu; see Section 4.2.2.

OPTION FEEDBACK

Allows feedback characters from an optional device to
be returned to the host device, in the format of

[CR], where:

A - Is the device type: R = RFID; and, S = Linear Scanner

B - Is the status: C = entire label complete; F = faulted

(failed) label; and, U = unknown

C - Is the number of expected reads, given in two

characters.

D - Is the number of good reads, given in two characters.

E - Is the internal Job and Sub Job Identifier, given in four

characters each.

F - Is the data read, delimited with semicolons (;) if multiple

reads.

DISABLED

Reports no data.

SCANNER

Reports Linear Scanner data.

RFID HEX

Reports RFID data in hexadecimal format.

RFID ASCII

Reports RFID data in an ASCII format.

PROCESS SOH (DATA)

Determines the response to an Immediate Command

(e.g., Get Status, Module Storage, etc.), where:

DISABLED

Processes commands normally.

ENABLED

Interrupts operations upon SOH receipt to process the

command.