22.14Arming Station with SecvestKey functionality

Installer Menu

Æ Testing Æ Secvest Key

Select the corresponding Secvest Key 2WAY wireless cylinder (Door
Lock 1, Door Lock 2, Door Lock 3 or Door Lock 4). The wireless
cylinder functions and correct positioning of DIP switch 3 to the door
hinge in the Secvest Key 2WAY can be tested here.

“Unlocked” is shown on the Secvest 2WAY display when the door is
unlocked. “Locked” is shown when the button on the Secvest Key
2WAY wireless cylinder is pressed and the door is then locked. The
received signal strength is also shown.

23. Viewing the log

A list of log displays can be found in the user manual.

24. About Panel

Select the About Panel menu item.

An overview of the displayed data is shown in the following table:

Main S/W:

Software status of the firmware in the alarm centre

Part No.:

Software status of the firmware in the alarm centre

Radio:

Software status of the wireless communication

German:

Software status of the OSD language