ABUS FU8007 Secvest 2WAY Base Kit Installation User Manual

Page 84

background image

84

Battery fault OK

-

-

-

YR

Battery missing

-

-

-

YM

Battery missing OK

-

-

-

YR

ISDN/GSM fault

-

-

-

LT

ISDN/GSM fault OK

-

-

-

LR

PSTN fault

-

-

-

LT

PSTN fault OK

-

-

-

LR

Jamming

-

-

XQ

XQ

Supervision fault

-

-

BZ

BZ

Supervision fault OK

-

-

-

-

RF battery fault

-

-

XT

XT

Set

-

CL

CL

CL

Internal active

-

CL

CL

CL

Unset

-

OP

OP

OP

Key switch set

CS

CS

CS

CS

Key switch unset

OS

OS

OS

OS

Download successful

-

-

RS

RS

Tamper user code

-

JA

JA

JA

Omit zone

BB

BB

BB

BB

Man. trigger test report

RX

RX

RX

RX

Period. test report

RP

RP

RP

RP

Time / day changed

-

-

-

JT

Prog. mode start

-

LB

LB

LB

Prog. mode end

-

LS

LS

LS

User code changed

-

-

-

JV

User code deleted

-

-

JX

Default password setting
loaded

-

-

RH

RH

End time limit

EA

EA

EA

EA

User 00

= Installer

User 01

= Admin User

User 02-50

= User

User 51

= Quick set

User 52

= Key Sw Latched/ Key Sw Moment

User 53

= Downoader

20.1.10 SIA Report Restorals

Select whether the restoration of a function (closing of an alarm zone, error clearance)
should be transmitted to the command centre. If this function is disabled, only faults or
alarms are transmitted to the command centre but not the restoration (OK message) of
this function.

20.1.11 Contact ID Reports

Select whether the restoration of a function (closing of an alarm zone, error clearance)
should be transmitted to the command centre. If only the basic function is enabled,
only faults or alarms are transmitted to the command centre but not the reset of this
function.

All transmitted messages are listed in the table. If “Basic + Restore” is selected, then
all messages plus their reset command are transmitted.

Trigger

CID Basic code with zone
no. and user

CID Basic + Restore
code with zone no. and
user

Medical control panel

100

100

Social care

101

101

Fire

110

110

Fire control panel

110

110

The following connection is recommended in Germany and Austria:
Under “Report Type”, select SIA 1
Under SIA Report, select Basic
The codes are now transmitted according to the table without zone
numbers and users.
Under SIA Report, select Sum
The codes are now transmitted again according to the table without zone
numbers and users.
Under SIA Report, select Middle
The codes are now transmitted again according to the table with zone
numbers and users added.