Function
Meaning
Local
Tests the function of the local sirens in the alarm centre.
Loudspeaker
Tests the function of the local loudspeaker in the alarm
centre.
Keypad
Tests the keypad input function.
Walk Test
Used to go through each trained detector and test its
function.
Detector Signals
Tests the signal strength of the trained detectors.
Ext Sirens
Tests the signal strength of the external sirens.
WAM
Tests the signal strength of the wireless accessory
module.
Arming Station
Tests the signal strength of the arming station.
Outputs
Tests the outputs through manual activation.
Telecommands
Tests the button functions and the owner of the trained
remote control units (telecommands).
Pendants
Tests the function of the emergency call transmitter
(pendant).
PA Detector
Tests the function of the panic detector.
Tag
Tests the function of the chip key (tag).
Secvest Key
Tests the function of the Secvest Keys
22.1 Testing the local siren
Activate the siren by pressing On/Off.
After confirming with On/Off, the internal siren is activated. You should now hear the
alarm tone. ON is also shown in the top-right corner of the display.
To stop the test, press the control key under the On/Off display again.
22.2 Testing the loudspeaker
Activate the loudspeaker by pressing Play/Stop under the display.
After confirming with Play/Stop, the loudspeaker is activated. You should now hear the
voice messages. You can now listen to all voice messages saved in the display.
Playing is also shown in the top-right corner of the display. The following graphic
display is shown:
To stop the test, press the control key under the Play/Stop display again.
22.3 Testing the keypad
Press all keys on the keypad in succession. Press the double keys simultaneously to
start the test. The corresponding character is shown on the display in response.