8.11 Closing the alarm centre
Reconnect the top part to the base plate. Remember to connect the connection cable
of the base plate to the alarm centre. At the same time, check that all other
connections (emergency power supply and loudspeaker) are correctly connected to
the top part.
Close the alarm centre and attach it to the bottom part using the housing screws.
Do not connect to 230 V AC mains power supply until the alarm centre is correctly
fitted.
8.12 Notes on testing the alarm centre
To test the alarm centre functions without fixing it to the wall and without 230 V AC
mains voltage, the system must be activated using the kickstart.
After inserting the charged batteries, put the wireless alarm centre into operation by
short-circuiting the kickstart jumper on the upper side of the alarm centre.
8.13 Final tasks
All connections are now made and the wireless alarm centre is ready for
programming.
Note: When connecting the alarm centre to the power supply for the first time,
you are prompted to select the language used for the display. The standard
programming options for a certain country are then loaded.
The alarm centre is now in user mode, irrespective of whether it was put into
operation through connection to the 230 V AC mains voltage or using the kickstart
jumper.
Before starting programming, read the explanation of terms in the following chapter.
If you are familiar with these terms, you can skip the next chapter and start
programming the alarm centre.
8.14 Code reset (code default)
You can carry out a code reset if you have forgotten your installer or administration
code. All user settings (including trained remote controls) are deleted, and the
administrator and installer codes are reset to the factory default settings. Settings in
the installer menu are kept.
The installer code is then 7890.
The administrator code is then 1234.
The tamper switch housing must not be pressed.
1.
Disconnect the alarm centre from the
power supply (remove PSU and battery
connection).
2.
Short-circuit the Codes Defaulted jumper.
3.
Connect the power supply.
4.
The signal tone sounds.
5.
Remove the Codes Defaulted jumper.