Fire control panel OK

-

110

Fire OK

-

110

Panic

120

120

Panic control panel

120

120

Panic control panel OK

-

120

Panic OK

-

120

Duress

121

211

Burglary

130

130

Burglary OK

-

130

Cover tamper contact

137

137

Cover tamper contact OK

-

137

Tamper ext. siren

137

137

Tamper ext. siren OK

137

137

Tamper sensor

137

137

Tamper sensor OK

137

137

Tamper system

137

137

Tamper system OK

137

137

Key box open

150

150

Key box closed

150

150

Technical alarm

-

150

Technical alarm OK

150

150

Power failure

301

301

Power failure OK

-

301

Reset

305

305

Battery fault

311

311

Battery fault OK

-

311

Battery missing

311

311

Battery missing OK

-

311

ISDN/GSM fault

351

351

ISDN/GSM fault OK

-

-

PSTN fault

351

351

PSTN fault OK

-

-

Jamming

380

380

Supervision fault

381

381

Supervision fault OK

-

-

RF battery fault

384

384

Set

401

401

Internal active

401

401

Unset

401

401

Key switch set

409

409

Key switch unset

409

409

Download successful

412

412

Tamper user code

461

461

Omit zone

573

573

Man. trigger test report

601

601

Period. test report

602

602

Time / day changed

625

625

Prog. mode start

627

627

Prog. mode end

628

628

User code changed

-

-

User code deleted

-

-

Default password setting
loaded

-

-

End time limit

-

-

When the “CONTACT ID Basic” report type is selected, the codes are transferred
according to the table including the zone numbers and users.

20.1.12 Force Test Call Now

Use this option to start a test call immediately on the wireless alarm centre.
Select the Force Test Call Now menu item.

When Force Test Call Now is confirmed with Select, the wireless alarm centre opens
communications with the emergency command centre immediately.

20.1.13 Dynamic Test Call

Select whether the wireless alarm centre should make a test call every 24 hours.
If the function is enabled, the call is made every 24 hours following the last
transmission.

20.1.14 Static Test Call

When a static test call is selected, the system makes a test call at a certain time or day
of the month.

To make a test call at a specific time every day, select Reporting -> ALARMS -> Static
Test Call -> Daily.
Enter a number between 01 and 24 on the display to select the call time. For example,
when 20 is entered, the wireless alarm centre makes a static test call at 20:00 every
day.

The dynamic test call has the advantage that a test transmission is only
made to the command centre when no transmissions have been made in
the previous 24 hours. If the “Enable/Disable” transmission is
programmed, then it can occur that no test transmissions are made for
several days when the system is enabled or disabled once per day.