ABUS FU8007 Secvest 2WAY Base Kit Installation User Manual
Page 85

85
Fire control panel OK
-
110
Fire OK
-
110
Panic
120
120
Panic control panel
120
120
Panic control panel OK
-
120
Panic OK
-
120
Duress
121
211
Burglary
130
130
Burglary OK
-
130
Cover tamper contact
137
137
Cover tamper contact OK
-
137
Tamper ext. siren
137
137
Tamper ext. siren OK
137
137
Tamper sensor
137
137
Tamper sensor OK
137
137
Tamper system
137
137
Tamper system OK
137
137
Key box open
150
150
Key box closed
150
150
Technical alarm
-
150
Technical alarm OK
150
150
Power failure
301
301
Power failure OK
-
301
Reset
305
305
Battery fault
311
311
Battery fault OK
-
311
Battery missing
311
311
Battery missing OK
-
311
ISDN/GSM fault
351
351
ISDN/GSM fault OK
-
-
PSTN fault
351
351
PSTN fault OK
-
-
Jamming
380
380
Supervision fault
381
381
Supervision fault OK
-
-
RF battery fault
384
384
Set
401
401
Internal active
401
401
Unset
401
401
Key switch set
409
409
Key switch unset
409
409
Download successful
412
412
Tamper user code
461
461
Omit zone
573
573
Man. trigger test report
601
601
Period. test report
602
602
Time / day changed
625
625
Prog. mode start
627
627
Prog. mode end
628
628
User code changed
-
-
User code deleted
-
-
Default password setting
loaded
-
-
End time limit
-
-
When the “CONTACT ID Basic” report type is selected, the codes are transferred
according to the table including the zone numbers and users.
20.1.12 Force Test Call Now
Use this option to start a test call immediately on the wireless alarm centre.
Select the Force Test Call Now menu item.
When Force Test Call Now is confirmed with Select, the wireless alarm centre opens
communications with the emergency command centre immediately.
20.1.13 Dynamic Test Call
Select whether the wireless alarm centre should make a test call every 24 hours.
If the function is enabled, the call is made every 24 hours following the last
transmission.
20.1.14 Static Test Call
When a static test call is selected, the system makes a test call at a certain time or day
of the month.
To make a test call at a specific time every day, select Reporting -> ALARMS -> Static
Test Call -> Daily.
Enter a number between 01 and 24 on the display to select the call time. For example,
when 20 is entered, the wireless alarm centre makes a static test call at 20:00 every
day.
The dynamic test call has the advantage that a test transmission is only
made to the command centre when no transmissions have been made in
the previous 24 hours. If the “Enable/Disable” transmission is
programmed, then it can occur that no test transmissions are made for
several days when the system is enabled or disabled once per day.