ABUS FU8007 Secvest 2WAY Base Kit Installation User Manual
Page 81
81
20.1.1 Call mode
Select the corresponding function. For a list of functions and their attributes, see the
table below.
Function
Meaning
Deactivated
No alarm messages are transmitted to the command
centre.
Single
The alarm centre transmits alarm messages to the first
phone number in the phone book together with the first
account number for identification. If transmission if not
confirmed,
the centre repeats the call up to 15 times.
Alternate
The alarm centre first transmits alarm messages to the
first phone number in the phone book. If the line is busy,
the alarm is transmitted to the second number in the
phone book. This continues up to 15 times until
confirmed, always alternating between the two phone
numbers.
20.1.2 Primary telecoms
Select which primary transmission path should be used. This transmission path is used
as long as transmission is possible using it.
20.1.3 Phone Book (ALARMS)
Select which number should be changed. Enter the callback number of the command
centre that you received for transmitting the respective report. Press the star key to
enter a dial pause. Each dial pause interrupts the dial procedure for 3 seconds.
20.1.4 IP-Network
IP address for alarm messages
When an ethernet module is attached, the wireless alarm centre can report alarms to a
suitable receiver over the Internet. There are two types of receivers, an IRIS Polling
Engine or a special application that runs on the PC of the alarm reception. A separate
IP address must be saved for each receiver type. Two IP addresses can be entered
when communicating with the alarm reception using a receiver. The wireless alarm
centre sends data to the second IP address in the alarm reception when the call to the
first IP address fails and
Reporting, Alarms, Call Mode, Alternate
is selected.
This menu also offers a storage location for the character string used by the receiver to
identify each individual wireless alarm centre. This identification code depends on the
account number of the alarm reception.
The available options are as follows:
Wireless alarm centre name
Enter a character string of up to 32 characters. This character string must be unique
for each wireless centre that communicates with a receiver.
IP address of the Polling Engine
Enter the IP address of the IRIS Polling Engine. The IP address consists of four
groups. Each group is three digits long and separated from the next group by a “dot”,
e.g. “192.168.000.001”. Press “ * ” to enter the dot.
IP address 1 of the alarm reception
Enter the main IP address of the alarm reception.
IP address 2 of the alarm reception
Enter the alternative IP address of the alarm reception.