Network Error (see note 3)
Tamper Alarm
Unset (see note 1)
Set (see note 1)
Zone Omitted (see note 2)
Medical Alarm
Key Box

The channels are preset as follows:

Channel

Setting

1

Fire

2

Panic

3

Burglary

4

Enabled / Disabled

5

Omit

6

Not Used

7

Not Used

8

Technical

20.1.8 FF Report Restorals

Select whether the restoration of a function (closing of an alarm zone, error clearance)
should be transmitted to the command centre. If this function is disabled, only faults or
alarms are transmitted to the command centre but not the restoration (OK message) of
this function.

20.1.9 SIA Report Mode

Select this, then select the Level of the transmission. The following table details which
events should be transmitted for the SIA 1 report.

Trigger

Basic SIA
code
without
zone no. or
user

Sum SIA
code without
zone no. or
user

Middle SIA
code with
zone no.
and user

Complete SIA
code with
zone no.
and user

Medical control panel

MA

MA

MA

MA

Social Care

QA

QA

QA

QA

Fire

FA

FA

FA

FA

Fire control panel

FA

FA

FA

FA

Fire control panel OK

-

FR

FR

FR

Fire OK

-

FR

FR

FR

Panic

PA

PA

PA

PA

Panic control panel

PA

PA

PA

PA

Panic control panel OK

-

PR

PR

PR

Panic OK

-

PR

PR

PR

Burglary

BA

BA

BA

BA

Burglary OK

-

-

BR

BR

Cover tamper contact

-

TA

TA

TA

Cover tamper contact OK

-

-

TR

TR

Tamper ext. siren

-

-

TA

TA

Tamper ext. siren OK

-

-

TR

TR

Tamper sensor

TA

TA

TA

TA

Tamper sensor OK

-

-

TR

TR

Tamper system

-

TA

TA

TA

Tamper system OK

-

-

TR

TR

Key box open

-

-

BA

BA

Key box closed

-

-

BR

BR

Technical alarm

-

UA

UA

UA

Technical alarm OK

-

UR

UR

UR

Power failure

-

-

-

AT

Power failure OK

-

-

-

AR

Reset

-

OR

OR

OR

Battery fault

-

-

-

YT

1. Open and close have the same functions as “Open/Close”, but are
made on two separate channels.
2. Zone blocked: The wireless alarm centre sends this signal for five
seconds when the user blocks a zone.
3. The wireless alarm centre either delays the reporting or logging of
network errors, or exits the installation menu with a network error after
15-18 minutes (random selection). In Germany, the wireless alarm
centre waits at least 60 minutes before reporting.