Function

Meaning when system is
activated

Meaning when system is
deactivated

Deactivated

No response.

No response.

Fault

Fault is reported by telephone.

Fault is reported on the
display and by signal tone.

Tamper

External alarm.
Transmission of supervision
failure and tamper.

Fault is reported on display
and by signal tone.
External alarm.
Transmission of supervision
failure and tamper.

Alarm

External alarm.
Transmission of supervision
failure and alarm.

Alarm message on display
and signal tone.

This option is used to fulfil the wireless supervision demands listed under
guideline EN 50131-3.

17.13 Jamming

Select whether the alarm system should display a warning in the case of jamming
detection. If this function is enabled, a warning is shown on the display if jamming is
detected.

Installer Menu

Æ System Options Æ Jamming Æ Disabled

Fault
Fault + Sounders

xFactory setting: Disabled

xIf “Fault” is selected, a warning is shown on the display when jamming is

detected. If an output is programmed for jamming, then this is switched.
Communication measures set accordingly are also started.

xIf “Fault + Sounders” is selected, all signallers are also activated.

oNote: This setting does not conform to EN50131 standards!

17.14 Batt Load Test

Select whether the alarm system should test the battery capacity at every disarming
or every 23 hours.
If the function is disabled, the system tests other less important
functions every hour.

17.15 Siren in PSet

When Activated is selected, the alarm system also starts a local alarm when activated
internally.
When the function is deactivated, only an internal alarm is triggered when the system
is activated internally. When programmed, trans-mission of the alarm to a security
centre (optional) is made every time.

When this option is activated, the wireless centre prevents the user from
activating the system when a detector has lost contact with the wireless
centre for more than 15 minutes.

When the wireless centre communicates or plays / records a message,
the test is delayed until these activities are finished. If no mains power is
present, the wireless centre makes the test as soon as it is reconnected.